Configuration

Use this page to configure the main operating parameters for GateKeeper before the system is taken into service.

Basic Settings

Configure the core behavior for the installed unit.

ProgramProgram type installed in the device.

Select the program used to control the gate, boom, carousel, or door.

Parameter

Index Range Format Factory setting Example
GKEPRG 1..2 0..5

0 = Deactivated

1 = Gate without end-stop sensors

2 = Gate with end-stop sensors

3 = Carousel

4 = Boom

5 = Door

0

GKEPRG 1

Access-Control Mode

Select the normal access-control mode used by GateKeeper when no planned schedule change is active.

Parameter

Index Range Format Factory setting Example
GKEACC 1..2 0..6

0 = Permanently closed
1 = Permanently open
2 = Access control
3 = Access control with road sensor

4 = Calendar-based access control

5 = Closed but everyone can open

6 = Closed but everyone can open with road sensor

2

GKEACC 0

Custom Text

GateKeeper can store a custom unit name and a custom greeting text.

Name

Store a custom GateKeeper name text.

Parameter

Index Range Format Factory setting Example
GKENAVN - Stored text value Text string Blank GKENAVN Main Gate

Greeting

Store a custom GateKeeper greeting text.

Parameter

Index Range Format Factory setting Example
GKEHILS - Stored text value Text string Blank GKEHILS Welcome

Scheduled Switching

Use these parameters for a one-time planned change of the GateKeeper access state. Both the start time and the stop time must be configured. At the start time, GateKeeper applies the configured start state. At the stop time, GateKeeper applies the configured stop state and clears the scheduled switching values.

Access-Control Start

Select the direct access-control state that GateKeeper must apply at the planned start time.

Parameter

Index Range Format Factory setting Example
GKEACCSTART 1..2 0,1,2,3,5

0 = Permanently closed
1 = Permanently open
2 = Access control
3 = Access control with road sensor
5 = Closed but everyone can open

0

GKEACCSTART 2

Access-Control Start Time

Set the exact planned start time for the scheduled change. Scheduled switching stays inactive until both the start time and the stop time are set.

Parameter

Index Range Format Factory setting Example
GKEACCSTARTTIME 1..2 0..2147483647

Planned start timestamp for scheduled switching

0

GKEACCSTARTTIME 1714978800

Access-Control Stop

Select the direct access-control state that GateKeeper must apply when the stop time is reached.

Parameter

Index Range Format Factory setting Example
GKEACCSTOP 1..2 0,1,2,3,5

0 = Permanently closed
1 = Permanently open
2 = Access control
3 = Access control with road sensor
5 = Closed but everyone can open

0

GKEACCSTOP 0

Access-Control Stop Time

Set when GateKeeper must end the planned state and switch to the configured stop state.

Parameter

Index Range Format Factory setting Example
GKEACCSTOPTIME 1..2 0..2147483647

Planned stop timestamp for scheduled switching

0

GKEACCSTOPTIME 1714982400

Road Sensor Inputs

Enable the road-sensor inputs used by the road-sensor-based access modes.

Inside Road Sensor

Enable the inside road-sensor input for the selected GateKeeper slot.

Parameter

Index Range Format Factory setting Example
GKERSIN 1..2 0..1

0 = Disabled
1 = Activated

0

GKERSIN 1

Outside Road Sensor

Enable the outside road-sensor input for the selected GateKeeper slot.

Parameter

Index Range Format Factory setting Example
GKERSOUT 1..2 0..1

0 = Disabled
1 = Activated

0

GKERSOUT 1

Auto-Close Timer

Set how long GateKeeper waits before it closes again after an approved opening cycle.

Parameter

Index Range Format Factory setting Example
GKECLOTIM 1..2 0..32767

Delay in seconds before GateKeeper closes again

1

GKECLOTIM 10

Public revision 21/08/2026