GateKeeper LX4 PRO IODigital input/output. list

Terminal layout and jumper settings for GateKeeper LX4 PRO.

Controller Mounting Power supply Digital inputs Digital outputs Analog inputs Analog outputs

Model: LX4 PRO

DIN-rail mounting 8-36 VDC 8 8 4 2

SIM card

Insert a SIM card if the unit is not factory delivered with a SIM card:

Power supply

Power supply Terminal Use Note
8-36 VDC

28 - SUPP

29 - SUPP

Plus

Minimum 12 V if 0-10 V outputs are used.

Minimum 16 V if S0IEC 62053-31 Class A S0 standard for pulse signals./NPNNPN is a negative signal (minus). inputs are used.

27 - PGND Minus

Digital inputs

Digital inputs Terminal Use Note
Ground 1 40 - SGND Ground for inputs 1..4 Must always be connected.
Input 1 41 - DI1

Motor 1 status (0 = Stopped, 1 = Running)

If jumper 1 is in position N, the DI1 signal must be 8-40 VDC (PNPPNP is a positive signal (plus).).

If jumper 1 is in position S, the signal must be between SGND and DI1 (S0IEC 62053-31 Class A S0 standard for pulse signals./NPNNPN is a negative signal (minus).).

Input 2 42 - DI2

Sensor 1 open (0 = Not open, 1 = Open)

If jumper 2 is in position N, the DI2 signal must be 8-40 VDC (PNPPNP is a positive signal (plus).).

If jumper 2 is in position S, the signal must be between SGND and DI2 (S0IEC 62053-31 Class A S0 standard for pulse signals./NPNNPN is a negative signal (minus).).

Input 3 43 - DI3

Sensor 1 closed (0 = Not closed, 1 = Closed)

If jumper 3 is in position N, the DI3 signal must be 8-40 VDC (PNPPNP is a positive signal (plus).).

If jumper 3 is in position S, the signal must be between SGND and DI3 (S0IEC 62053-31 Class A S0 standard for pulse signals./NPNNPN is a negative signal (minus).).

Input 4 44 - DI4

Road sensor 1 outside area (0 = No vehicle detected, 1 = Vehicle detected)

If jumper 4 is in position N, the DI4 signal must be 8-40 VDC (PNPPNP is a positive signal (plus).).

If jumper 4 is in position S, the signal must be between SGND and DI4 (S0IEC 62053-31 Class A S0 standard for pulse signals./NPNNPN is a negative signal (minus).).

Input 5 45 - DI5 Road sensor 1 inside area (0 = No vehicle detected, 1 = Vehicle detected) The DI5 signal must be 8-40 VDC (PNPPNP is a positive signal (plus).).
Input 6 46 - DI6 Motor 2 status (0 = Stopped, 1 = Running) The DI6 signal must be 8-40 VDC (PNPPNP is a positive signal (plus).).
Input 7 47 - DI7 Sensor 2 open (0 = Not open, 1 = Open) The DI7 signal must be 8-40 VDC (PNPPNP is a positive signal (plus).).
Input 8 48 - DI8 Sensor 2 closed (0 = Not closed, 1 = Closed) The DI8 signal must be 8-40 VDC (PNPPNP is a positive signal (plus).).
Ground 2 49 - SGND Ground for inputs 5..8 Must always be connected.

Digital outputs

Digital outputs Terminal Use Note
Power supply 8-36 VDC 30 - DOUT SUPP + Supply voltage for outputs

Terminal 30 can be connected to terminal 29.
Terminal 39 can be connected to terminal 27.

39 - DOUT GND -
Output 1 31 - DO1 Contact set 1, NONormally open.

Maximum load is 1.5 A per output.

Maximum inductance for switching is 20 mH per output.

Output 2 32 - DO2 Contact set 2, NONormally open.
Output 3 33 - DO3 Contact set 3, NONormally open.
Output 4 34 - DO4 Contact set 4, NONormally open.
Output 5 35 - DO5 Contact set 5, NONormally open.
Output 6 36 - DO6 Contact set 6, NONormally open.
Output 7 37 - DO7 Contact set 7, NONormally open.
Output 8 38 - DO8 Contact set 8, NONormally open.

Public revision 21/08/2026