Terminal layout and jumper settings for GateKeeper NX 910.
|
Documentation for:
|
![]() |
| Controller | Mounting | Power supply | Digital inputs | Relay outputs | Analog inputs | Analog outputs |
Model: NX 910 |
Wall mounting | 8-36 VDC or 230 VAC | 5 | 4 | 2 | 0 |
Insert a SIM card if the unit is not factory delivered with a SIM card:
| Power supply | Use | Terminal | Note |
| 230 VAC | L1 (100-260 VAC / 50/60 Hz) | P | 24 V and 230 V can be connected at the same time. |
| Neutral | N | ||
| Protective earth | |||
| 24 VDC | Plus | DCIN | |
| Minus | XGND |
| Digital inputs | Use | Terminal | Note |
| Input 1 | Motor status (0 = Stopped, 1 = Running) | DI1 (PNP or NPN) |
If the JPDI1 jumper is in position N, the DI1 signal must be 8-40 VDC (PNP). If the JPDI1 jumper is in position S, the signal must be between GND and DI1 (S0/NPN). |
| Input 2 |
Sensor open (0 = Not open, 1 = Open) |
DI2 (PNP or NPN) |
If JPDI2 is in position N, the DI2 signal must be 8-40 VDC (PNP). If JPDI2 is in position S, the signal must be between GND and DI2 (S0/NPN). |
| Input 3 |
Sensor closed (0 = Not closed, 1 = Closed) |
DI3 (PNP or NPN) |
If JPDI3 is in position N, the DI3 signal must be 8-40 VDC (PNP). If JPDI3 is in position S, the signal must be between GND and DI3 (S0/NPN). |
| Input 4 | Road sensor outside area (0 = No vehicle detected, 1 = Vehicle detected) | DI4 (PNP or NPN) |
If JPDI4 is in position N, the DI4 signal must be 8-40 VDC (PNP). If JPDI4 is in position S, the signal must be between GND and DI4 (S0/NPN). |
| Input 5 | Road sensor inside area (0 = No vehicle detected, 1 = Vehicle detected) | DI5 (PNP) | Use only PNP signal. |
| Ground | Ground for inputs 1..5 | GND | Must always be connected. |
| Relay outputs | Use | Terminal | Note |
| Output 1 | Open (0 = Closes, 1 = Opens and stays open) | R1A and R1B (NO) | For sliding gates, doors, and barriers. |
| Output 2 | Open (0 = Closed, 1 = Closes and stays closed) | R2A and R2B (NO) | For carousels where 2 directions must be controlled. |
| Output 3 | Status (0 = No access control, 1 = Access control enabled) | R3A and R3B (NO) | A lamp can show whether access control is enabled. |
| Output 4 | Fault (1 = System fault) | R4A and R4B (NO) | A lamp can show when the system has a fault. |
| DC output | Use | Terminal | Note |
| DC output 12/24 VDC, max 500/250 mA | Extra 12/24 VDC supply voltage, max 500 mA @ 12 V and max 250 mA @ 24 V | DCOUT |
Factory set to 24 V, jumper fitted. |
| Ground | Ground for DC | SGND | - |