Supported settings

Use this page to determine which monitoring information, settings, and commands NaviGuard provides for each connected instrument model.

Model-dependent capability: Available information and controls depend on the connected instrument model and the installed NaviGuard software.

How to read the capability tables

Mark Meaning
Y The model provides the capability. Use the section below the table for its available choices.
R Read-only. NaviGuard can show the confirmed value or state but cannot change it.
R-W Read/write. NaviGuard can show and change the value through the model-specific settings path.
- Not supported. NaviGuard does not show a control for it.

Lantern capabilities

Compare the four model-specific functions below. Monitoring information is documented separately and is not repeated in this settings matrix.

Lantern model Operating Mode Nominal Range Primary Flash Character Alternate Flash Character Select Active Character Day/Night Switching
MSM MCL360 Y R-W - - R-W R-W
Tideland MaxiHalo-60 or Nova-65 with Halo2 Controller Y R-W R-W Y R-W R-W
Tideland Rotator with MaxiHalo60 and Halo2 Controller Y R-W R-W Y R-W R-W
Tideland SolaMax with Halo2 Controller Y R-W R-W Y R-W R-W
Tideland Flasher with MaxiHALO-60 II Controller Y R-W R-W Y R-W R-W
Tideland Rotator with MaxiHALO-60 II Controller Y R-W R-W Y R-W R-W
Tideland Quad Controller Lights, Nova-250, MaxLED-180, MasterRange Y R-W R-W Y R-W R-W
MSM MBL-series MF12 Y R-W - - - R-W
MSM MBR-series PPC02 Y R-W - - - R-W
Tideland NOVA-65 ES-1071 non-solar - R - - R R
Tideland NOVA-65 ES-1071 solar - R - - R R

Settings and commands

Open Settings for the technician procedure.

Operating mode

Operating Mode lets you select Automatic, Always On, or Always Off when the lantern supports this function.

Parameter Index Range Format Default Example
NAGMODE# 1..6 0..2

0 = Automatic

1 = Always On

2 = Always Off

0 NAGMODE1 0

Nominal range

Nominal Range is shown in nautical miles. The available choices depend on the selected lantern.

ParameterIndexRangeFormatDefaultExample
NAGRANGE#1..6Model-specificNominal range in nautical miles-NAGRANGE1 5

Flash characters

Primary and Alternate use the same Flash Characters list. Alternate and Select Active Character are available only when the connected model supports two stored characters.

Primary flash character

ParameterIndexRangeFormatDefaultExample
NAGFLASH#1..6Flash Characters supported by the selected lanternNaviGuard ID-NAGFLASH1 <id>

Alternate flash character

ParameterIndexRangeFormatDefaultExample
NAGFLASHALT#1..6Flash Characters supported by the selected lanternNaviGuard ID-NAGFLASHALT1 <id>

Select active character

ParameterIndexRangeFormatDefaultExample
NAGFLASHSEL#1..60..1

0 = Primary

1 = Alternate

-NAGFLASHSEL1 0

Day/night switching

Day/Night Switching lets you set the light levels for switching the lantern on and off when this function is supported.

Switch on below

ParameterIndexRangeFormatDefaultExample
NAGLUXON#1..6Values supported by the selected lanternSwitch-on level in luxCurrent lantern valueNAGLUXON1 <lux>

Switch off above

ParameterIndexRangeFormatDefaultExample
NAGLUXOFF#1..6Values supported by the selected lanternSwitch-off level in luxCurrent lantern valueNAGLUXOFF1 <lux>

Other instrument types

PowerMonitor, PowerGuard, breaker, Racon, and other instrument capabilities must be added as separate instrument-type sections. Do not infer settings or commands from a lantern model or from a telemetry value.

Complete model list

See the Maritime Signalling model reference for the complete connected-device list and communication support.


Public revision 21/08/2026