DataGuard via 1-Wire

Use this page when a configured 1-Wire channel must be logged in DataGuard or exported onward to Emiko.

The 1-Wire source setup is documented on 1-Wire Temperature Monitoring > Setup and alarms. This page explains when DataGuard is needed and owns the DataGuard reporting parameters for 1-Wire values.

Use DataGuard via Analog Inputs when the value comes from a physical analog input. Use DataGuard via Driver Communication when the value comes from a configured driver profile rather than a 1-Wire channel.

Complete Setup Workflow

When DataGuard is Needed

Activation Rules

Data is only sent when the same channel has a valid equipment type, data type, and log mode.

Typical Uses

Product Paths That Use 1-Wire DataGuard

Use the product page first when the 1-Wire value belongs to a product-specific setup. Use this page for the shared DataGuard reporting parameters.

Product path 1-Wire source DataGuard values Product setup
Standalone DataGuard Mapped 1-Wire temperature channel. OTEQT#=35 and the DTY required by the measured value. This page
OceanWatcher 1-Wire temperature sensor used as an OceanWatcher temperature value. Use OTEQT# and OTDATATYPE# for the selected OceanWatcher temperature path. OceanWatcher temperature setup
FlexVander Optional field temperature value, for example soil temperature. Use the equipment type and DTY required by the delivered field-value path. FlexVander LX9 eco IO list
WeatherStation Mapped 1-Wire temperature channel when the delivered WeatherStation setup uses that source. Use WeatherStation equipment type when the value belongs to WeatherStation. WeatherStation DataGuard setup

Worked Example

This example shows a 1-Wire temperature sensor on channel 1 that should still use normal local alarms, but also be logged and exported onward.

DataGuard Reporting Parameters

Configure these parameters after the 1-Wire sensor is enabled, discovered, and mapped to the correct logical channel.

Equipment Type

Select which Emiko equipment type should own the reported 1-Wire value.

Parameter Index Range Format Default Example
OTEQT# 1..10 0..35

0 = None (disabled)

1..35 = EQT value for the equipment in Emiko

Defined EQT IDs in this software:
1 = MarinePro (MAP)
2 = EnergyLogger (ENL)
3 = GateKeeper (GKE)
4 = SmartCharger (SMC)
5 = WaterStation (WAS)
6 = ShoreSupply (SSU)
7 = ReeferPedestal (REP)
10 = NaviLight (NLI)
11 = OnSiteLight (OSL)
12 = FlexGuard (FLG)
14 = EasyPump (EYP)
17 = EasyWash (EWA)
19 = Marinella (MAL)
20 = OceanWatcher (OWA)
21 = ServiceTower (SET)
22 = Marineium (MAU)
23 = WeatherStation (WST)
24 = Lantern (LNT)
25 = MarineMax (MMA)
26 = Gate2Gate (G2G)
31 = PowerGuard (PWG)
32 = TallyKey (TAL)
33 = Beas (BEA)
34 = DockPoint (DOP)
35 = DataGuard (DAG)

0 OTEQT1 35

Data Type

Select which data type the 1-Wire channel should be sent as in Emiko.

Parameter Index Range Format Default Example
OTDATATYPE# 1..10 0..1312

0 = None (disabled)

1..1312 = Data type (DTY) for the value sent to Emiko. See Shared Runtime Data Type Reference.

0 OTDATATYPE1 1101

Log Mode

Select how the 1-Wire value should be logged or exported for the selected channel.

Parameter Index Range Format Default Example
OTLOGMODE# 1..10 0..4

0 = None

1 = Periodic

2 = Periodic + threshold change

3 = Event

4 = Hybrid

1 OTLOGMODE1 2

Log Interval

Use this parameter when the selected log mode includes periodic logging.

Parameter Index Range Format Default Example
OTLOGINT# 1..10 0..31

0 = Disabled

10 = Every minute
11 = Every 2 minutes
12 = Every 5 minutes
13 = Every 10 minutes
14 = Every 15 minutes
15 = Every 20 minutes
16 = Every 30 minutes

17 = Every hour
18 = Every 2 hours
19 = Every 4 hours
20 = Every 6 hours
21 = Every 8 hours
22 = Every 12 hours

23 = Every day
24 = Every 2 days
25 = Every 3 days
26 = Every week
27 = Every 2 weeks
28 = Every month
29 = Every quarter
30 = Every half year
31 = Every year

19 OTLOGINT1 19

Log Hysteresis

Use this parameter when the selected log mode requires a minimum value change before a new value is stored.

Parameter Index Range Format Default Example
OTLOGHYS# 1..10 0..32767

0 = No change requirement

Other values = Temperature change

0 OTLOGHYS1 25

Related Source Setup

Use 1-Wire Temperature Monitoring > Setup and alarms for sensor discovery, channel mapping, alarms, and recipient setup.

Use Shared Runtime Data Type Reference when the installation requires a DTY lookup before selecting OTDATATYPE#.


Public revision 21/08/2026