Set parameters for ServicePedestal. Parameters must be set before the system can be put into service.
Basic settings for the equipment.
Load factory settings. All parameters are set to the specified factory settings.
Note that the equipment restarts
The following global parameter is adjusted automatically:
| Index | Range | Format | Factory setting |
Example |
|
| SEPFAC | - |
- |
- | - | SEPFAC |
Set which program the equipment must use.
| Index | Range | Format | Factory setting |
Example |
|
| SEPPRG | - | 0..71 |
0 = Disabled 1 = MarinePro 2 = MarinePro V1 with water outlet (generation 1) 3 = MarinePro V2 with water outlet (generation 2) 4 = MarinePro V3 with water outlet (generation 3) 10 = Marinella 11 = Marinella with water outlet 12 = Marinella NEO(V1) 13 = Marinella NEO with water outlet (V1)
20 = Marineium 21 = Marineium with water outlet
30 = MarineMax 40 = ShoreSupply (without consumption settlement) 41 = ShoreSupply 50 = TallyKey 51 = TallyKey with water outlet 60 = Beas 61 = Beas with water outlet 70 = DockPoint 71 = DockPoint with water outlet
0 = Disabled 1 = MarinePro 2 = MarinePro G2 10 = Marinella 20 = Marineium 30 = MarineMax 40 = ShoreSupply (without consumption settlement) 41 = ShoreSupply 50 = TallyKey 60 = Beas 70 = DockPoint |
0 | SEPPRG 1 |
Set how the customer is validated, or whether the equipment is available for free use.
| Index | Range | Format | Factory setting | Example | |
| - | 0..3 |
0 = Blocked (the equipment is blocked and cannot be used) 1 = Free (the equipment is open to everyone for free use, and all consumption is registered to the system account) 2 = Payment (the equipment validates the customer and only approved customers are accepted) 3 = Mixed (the equipment uses Payment first; if the customer is not approved, Free is used) |
2 | SEPACC 1 |
Set the equipment name. The name is used, for example, if the equipment sends a message.
| Index | Range | Format | Factory setting | Example | |
| SEPNAME | - | Max. 20 characters | Numbers or letters | - | SEPNAME Viking |
Set a greeting for the equipment. The greeting is used, for example, if the equipment sends a message.
| Index | Range | Format | Factory setting | Example | |
| SEPREGARDS | - | Max. 20 characters | Numbers or letters | - | SEPREGARDS Vikingegaarden |
Configure equipment modules. Note that modules are options and that the equipment can be supplied with or without modules.
Set whether the equipment has built-in transient protection.
| Index | Range | Format | Factory setting |
Example |
|
| SEPTPO | - | 0..2 |
0 = None 1 = Built in as NO 2 = Built in as NC |
0 | SEPTPO 1 |
Set whether the equipment has phase monitoring.
| Index | Range | Format | Factory setting |
Example |
|
| SEPFKO | - | 0..1 |
0 = None 1 = Built-in phase monitoring meter 2 = Monitoring via 3-phase energy meter 3 = Combined 1+2 |
0 | SEPFKO 1 |
Set whether the equipment has a built-in energy meter for registering internal power consumption.
| Index | Range | Format | Factory setting |
Example |
|
| SEPEGI | - | 0..1 |
0 = None 1 = Built in |
0 | SEPEGI 1 |
Set whether the equipment must control and monitor heating to protect water pipes against frost.
| Index | Range | Format | Factory setting |
Example |
|
| SEPHEAT | - | 0..1 |
0 = None 1 = Heating control |
0 | SEPHEAT 1 |
Set whether the equipment has built-in EnergyLogger for registering power consumption.
| Index | Range | Format | Factory setting |
Example |
|
| SEPEEL | - | 0..1 |
0 = None 1 = Built in |
0 | SEPEEL 1 |
Set whether the equipment has a built-in aKey key reader for registering, for example, RFID cards.
| Index | Range | Format | Factory setting |
Example |
|
| SEPAKR | - | 0..1 |
0 = None 1 = Built in |
0 | SEPAKR 1 |
Set parameters for power outlets.
Set how many power outlets the equipment is built with. For example, the equipment may be built with 4 power outlets.
| Index | Range | Format | Factory setting | Example | |
| SEPEAMOUNT | - | 0..12 |
0 = No outlets 1 = 1 outlet 2 = 2 outlets 3 = 3 outlets ... |
0 | SEPEAMOUNT 4 |
Set the time from when the plug is inserted until the power outlet must be switched on. If the time expires, the power outlet is paused. Another user can use the power outlet after the current plug is removed.
| Index | Range | Format | Factory setting | Example | |
| SEPEONTIM | - | 1..20 | Number of minutes | 8 | SEPEONTIM 10 |
Set the time from the last registered energy consumption until the power outlet is automatically switched off. For example, if a power outlet is switched on and no energy consumption is registered during the specified period, the power outlet is automatically switched off.
| Index | Range | Format | Factory setting | Example | |
| SEPEUSAGETIM | - | 0..32000 |
0 = Function disabled >0 = Number of minutes |
1440 (one day) | SEPEUSAGETIM 2880 |
Set parameters for water outlet.
Set the number of water outlet the equipment is built with. For example, the equipment may be built with 1 water outlet.
Must be selected before the equipment can be used
| Index | Range | Format | Factory setting | Example | |
| SEPWAMOUNT | - | 0..1 |
0 = No outlets 1 = 1 outlet |
0 | SEPWAMOUNT 1 |
Set the time from when operation is switched on until the water outlet must open. If the time expires, the user normally starts again, or another user can use the water outlet.
| Index | Range | Format | Factory setting | Example | |
| SEPWONTIM | - | 1..20 | Number of minutes | 8 | SEPWONTIM 10 |
Set the time from the last registered water consumption until the water outlet is automatically closed. For example, if a water outlet is opened and no water consumption is registered during the specified period, the water outlet is automatically closed.
| Index | Range | Format | Factory setting | Example | |
| SEPWUSAGETIM | - | 0..32000 |
0 = Function disabled >0 = Number of minutes |
1440 (one day) | SEPWUSAGETIM 2880 |
Set parameters for the valve.
Set which valve type is installed.
| Index | Range | Format | Factory setting | Example | |
| SEPVALTYPE# | 1..3 | 0..3 |
0 = None 1 = Solenoid valve (On/Off) 2 = Solenoid valve (Pulse) 3 = Motor valve BFA 820 |
0 | SEPVALTYPE 1 |
Set parameters for the water meter.
Set the water meter ratio. For example, 1 pulse corresponds to 10 liters of water.
| Index | Range | Format | Factory setting | Example | |
| SEPSCALE# | 1..3 | 0..1000 | Number of liters of water per pulse | 0 | SEPSCALE1 10 |
Set parameters for use of order number. When this function is used, the user can enter an order number, which is registered together with the power consumption. For example, when the user calls the equipment, an SMS is sent to the user, who must reply with the required order number. When the equipment receives an SMS with an order number, the power outlet is switched on.
Set the time from when the user receives the SMS until the user must reply with the order number. If the user does not reply before the time expires, the user must, for example, call again and a new SMS is sent.
| Index | Range | Format | Factory setting | Example | |
| SEPORDTIM | - | 1..8 | Minutes | 2 | SEPORDTIM 3 |
Set parameters for how the lighting must function.
Set operating mode. Lighting can be controlled manually or set to automatic. In automatic operation, the light turns on shortly before sunset and turns off shortly after sunrise.
| Index | Range | Format | Factory setting | Example | |
| SEPLIGHT | - | 0..2 |
0 = Always off 1 = Always on 2 = Automatic (recommended) |
2 | SEPLIGHT 1 |
Select output.
| Index | Range | Format | Factory setting | Example | |
| SEPLIGOUT | - | 0..7 |
0 = None 1 = Automatic (recommended) 2 = Output 1 3 = Output 2 4 = Output 8 5 = Output 16 6 = Output 28 7 = Output 40 |
1 | SEPLIGOUT 1 |
Status fields for reading values from the equipment.
Show the status of the equipment license.
|
Status |
Index | Range | Format | Factory setting | Example |
| LICSEP | - | - |
Bit 1: 1 = Power outlets 1..2 enabled Bit 2: 1 = Power outlets 3..4 enabled Bit 3: 1 = Power outlets 5..8 enabled Bit 4: 1 = Power outlets 9..12 enabled Bit 10: 1 = Water outlet enabled Bit 11: 1 = OrdreManager enabled |
- | Read-only |