MBO Cabinet Specifications

Specifications for the WaterStation MBO series cabinets.

Description WAS DN65-1 SEP /S MBO
Item numberItem number used when ordering from Vikingegaarden A/S.

1004429

Series

MBO

Model

Cabinet

Installation

Outdoor/indoor use

Power connection

Connected to ServicePedestal

Control box connections

1

Water inlet

1 x DN65/OD 75 mm PE100 PN10 pipe

Water outlet

1 x Storz B coupling 2 1/2"

Built-in GSMGSM (Global System for Mobile Communications) is a widely used standard for mobile communication and data. controller/data logger/control

-

Watertight

-

Lifting eyes

2

Flow meter - Manufacturer

Kamstrup

Flow meter - Flow Q1Q1 - minimum flow rate.

0,39 m3/h

Flow meter - Flow Q3Q3 - permanent flow rate.

63 m3/h

Flow meter - Class

R160

Flow meter - Approval

MIDMID refers to Measuring Instruments Directive certification for approved measuring instruments and manufacturer quality systems.

Flow meter - Communication

Pulse/10 L / M-Bus *

Valve - Opening time

10 seconds

Valve - Closing time

20 seconds

Valve - Function NCNormally closed. *

(power supply required)

TBSBackflow prevention valve that prevents water from flowing back into the waterworks supply line and helps protect drinking water from contamination. - Category * / **

4

Internal temperature

0-50 deg C

External temperature

-20-50 deg C

PN

10

Thermostatically controlled heater

yes

Cable entry seals for power cables

yes

Locking system

Square key

Surface treatment

Hot-dip galvanised

-Coating thickness measured in accordance with DS/EN ISO 1461

Local 93 µm / Average 93 µm

-Corrosion categories according to standard

ISO 12944-5

-Expected service life for corrosion category C5Corrosion category for coastal or offshore environments with high salinity, or indoor environments with near-permanent condensation and high pollution.-M (Marine)

10-20 years

-Expected service life for corrosion category C4Corrosion category for industrial outdoor environments with high humidity and aggressive atmosphere, or indoor environments with near-permanent condensation and high pollution. (Industrial)

20-40 years

Weight

-

External dimensions (HxWxD)

1450x1200x750 mm

* Option
** If the TBSBackflow prevention valve that prevents water from flowing back into the waterworks supply line and helps protect drinking water from contamination. valve is triggered, the liquid is discharged from the cabinet and there is no guarantee that liquid cannot overflow inside the cabinet due to the TBSBackflow prevention valve that prevents water from flowing back into the waterworks supply line and helps protect drinking water from contamination. valve design


Public revision 21/08/2026