Use this page to select the instrument path for a WeatherStation installation. See Instrument Families for the common list across products.
| Device | DEVMODEL# |
Connection path | WeatherStation use | Setup |
| Thies Clima - Auto | 107109100 |
RS485 / serial driver | Auto-detect supported Thies Hydro Termo Baro variants. | Driver |
| Thies Clima - WSC10 | 107109102 |
RS485 / serial driver | Compact weather station values. | Driver |
| Thies Clima - WSC11 | 107109103 |
RS485 / serial driver | Weather values such as wind, precipitation/status options, brightness/radiation, temperature, humidity, pressure, and GPS/time data. | Driver |
| GILL - MaxiMet GMX600 | 107110101 |
RS485 / serial driver | Compact weather station values including wind, temperature, humidity, pressure, precipitation, and compass/GPS options. | Driver |
| OTT CBS - Bubble Sensor | 107111101 |
RS485 / serial driver | Water level by bubble sensor principle. | Driver |
| Siemens - SITRANS LR110 | 107116101 |
RS485 / serial driver | 80 GHz radar level measurement up to 15 m. | Driver |
| Siemens - SITRANS LR120 | 107116102 |
RS485 / serial driver | 80 GHz radar level measurement up to 30 m. | Driver |
| Instrument | Connection path | WeatherStation use | Setup |
| Thermo/Hygro transmitter | 2 x AI | Temperature and humidity through analog transmitter signals. | Analog |
| Wind direction transmitter | AI | Wind direction from a 4-20 mA or 0-10 V analog signal, including current, 2-minute, 10-minute, spread, and state/QC reporting when DataGuard selectors are configured. | Analog |
| NRG 200M wind vane | Voltage AI | WeatherStation wind direction through DataGuard selector VRDATATYPE# 9012. The selector uses the 0.007 to 2.5 VDC signal and formula degrees = volts * 147.91 - 1.460. Use VRTYPE#=2, 4, or 5; do not use 4-20 mA. |
Assisted |
| RNRG/NRG 200P wind vane | Voltage AI | WeatherStation wind direction through DataGuard selector VRDATATYPE# 9013. Use VRTYPE#=2, 4, or 5, and set TMIN#/TMAX# to the conditioned post-input signal range in mV, normally 0 and 2500, 5000, or 10000. Do not use 9012 for 200P. |
Assisted |
| Generic 4-20 mA or 0-10 V transmitter | AI | Project-specific temperature, pressure, level, humidity, or other analog value. | Analog |
| Instrument | Connection path | WeatherStation use | Setup status |
| Pronamic / Rain Gauge Professional | DI/high-speed counter input | Tipping-bucket precipitation through DataGuard selector VRCDATATYPE# 9009 on a supported X32/NX32/NX32L high-speed counter input with TIN#=1 and rain profiles 2..5: 0,2, 0,1, 0,25, or 0,5 mm/tip. |
Assisted |
| Rain Gauge and Snow sensor Meteorological | DI/counter pulse input and related field-instrument setup | Precipitation and snow-related meteorological registration. | Assisted |
| Generic pulse instrument | DI/counter pulse input | Meter pulses, pulse flow, or other count-based field values. | Assisted |
| Thies 4.3519 cup anemometer via counter input (wind speed) | DI/high-speed counter input | Counter-based WeatherStation wind speed through DataGuard selector VRCDATATYPE# 9008, VRCPROFILE#=1, supported X32/NX32/NX32L high-speed counter input, and delivered installation wiring. The profile uses V = 0.07881 * f + 0.32. |
Assisted |
| NRG 40C anemometer | Conditioned DI/high-speed counter pulse input | Counter-based WeatherStation wind speed through DataGuard selector VRCDATATYPE# 9010 with VRCPROFILE#=6. The profile uses m/s = Hz * 0.765 + 0.35. Because NRG 40C is a low-level AC sine-wave sensor, use it only with signal conditioning or a verified clean countable pulse path into the controller input. |
Assisted |
| NRG 40H Hall-effect anemometer | DI/high-speed counter input with external supply and pull-up | Counter-based WeatherStation wind speed through DataGuard selector VRCDATATYPE# 9011 with VRCPROFILE#=7. The profile uses m/s = Hz * 0.765 + 0.35. The open-collector Hall output requires external supply and pull-up wiring for a countable controller input signal. |
Assisted |
Wind-speed selectors 9008, 9010, and 9011 use the same DataGuard child output values for quality/status, 2-minute speed and gust, and 10-minute speed and gust. v1 supports a maximum of two active wind-speed VRC slots across those selectors.
| Instrument | Connection path | WeatherStation use | Setup |
| 1-Wire temperature sensor | 1-Wire | Simple local temperature measurement, for example soil or field temperature. | 1-Wire |
Use official manufacturer documentation and the delivered installation specification for final sensor limits, mounting, wiring, and maintenance requirements.