Features and operating principles for OceanWatcher.
Power Supply
OceanWatcher must be connected to 230 V / 50 Hz.
Data Logging
Water-level logging is available as an option:
The water level is logged internally in the data logger and synchronized continuously with Emiko.
The logging interval can be configured.
Water-temperature logging is available as an option:
Water temperature is logged internally in the data logger and synchronized continuously with Emiko.
The logging interval can be configured.
Water-current logging is available as an option:
Water currents are logged internally in the data logger and synchronized continuously with Emiko.
Logging supports up to 10 water-current zones.
The logging interval can be configured.
Data Export to DMIDanish Meteorological Institute.
OceanWatcher can export data to DMIDanish Meteorological Institute. as an option:
Data is sent in real time to DMIDanish Meteorological Institute., typically every 10 minutes or on events and deviations.
Data export to DMIDanish Meteorological Institute. can be switched on and off.
Data Export to Website
OceanWatcher can send real-time data for live display on websites as an option:
Data is sent in real time to websites, typically every 10 minutes or on events and deviations.
Data export to websites can be switched on and off.
Battery Backup
The unit has built-in battery backup with automatic battery charging.
Monitoring
The following functions are monitored as a minimum:
Power supply connection and disconnection.
Backup battery failure.
The unit shuts down because the backup battery is depleted.
Serial communication failure.
Alarms are sent by SMSSMS is a text message that can be sent or received with a mobile phone. or email and to Emiko.
Level Reference
OceanWatcher measures water level relative to DVR90Danish Vertical Reference 1990., the Danish vertical reference point.
Public revision 21/08/2026
Cookies on Vika Help
Vika Help uses necessary browser storage and, if you allow it, statistics cookies for Google Analytics. You can accept all, reject all, or open settings.
Cookie settings
Choose which categories may be used on Vika Help.
NecessaryAlways on. Required to remember your consent choice and keep the documentation shell working as intended.
Allows Google Analytics to measure aggregate use of the documentation site.