Equipment defaults define the standard DEVMODEL, DEVNETPROFILE, DEVSLOT, and DEVADDR layout for supported Vika equipment.
Use this page when configuring or checking a standard WaterStation, Marinella, OnSiteLight, ServicePedestal, GateKeeper, OceanWatcher, or another documented equipment layout. The configured equipment and its ProSoft implementation must follow the applicable documented default unless an approved project-specific deviation exists.
Network profile shows the communication profile number, Slot shows the actual DEVSLOT# value for that layout, and Address shows the communication address when one is used.Layout for a ServicePedestal with LX4 PRO.
| Connected equipment | Network profile | Slot | Address | Note |
| Energy meter 1 | 1 | 1 | 100 | Power outlet 1 |
| Energy meter 2 | 1 | 2 | 101 | Power outlet 2 |
| Energy meter 3 | 1 | 3 | 102 | Power outlet 3 |
| Energy meter 4 | 1 | 4 | 103 | Power outlet 4 |
Layout for a ServicePedestal with VX40.
| Connected equipment | Network profile | Slot | Address | Note |
| Energy meters 1..15 | 1 | 1..15 | 100..114 | Power outlets 1..15 |
| Energy meters 16..21 | - | - | - | Reserved |
| Energy meter 22 | 1 | 22 | 115 | EnergyLogger consumption 1 |
| Energy meter 23 | 1 | 23 | 116 | Internal energy consumption |
| Energy meter 24 | 1 | 24 | 117 | EnergyLogger consumption 2 |
| Key reader 1 | 10 | 1 | 0 | Front-panel key reader for all power outlets |
| Key reader 2 | 10 | 2 | 10 | Operator-box key reader for water outlet 1 |
Layout for a ServicePedestal with IX400.
| Connected equipment | Network profile | Slot | Address | Note |
| Energy meters 1..15 | 1 | 1..15 | 100..114 | Power outlets 1..15 |
| Energy meters 16..21 | - | - | - | Reserved |
| Energy meter 22 | 1 | 22 | 115 | EnergyLogger consumption 1 |
| Energy meter 23 | 1 | 23 | 116 | Internal energy consumption |
| Energy meter 24 | 1 | 24 | 117 | EnergyLogger consumption 2 |
| Modbus to M-Bus gateway | 3 | 1 | 130 | Gateway for water-meter communication |
| Modbus to DALI gateway | 3 | 2 | 131 | Gateway for light communication |
| Key reader 1 | 10 | 1 | 0 | Front-panel key reader for all power outlets |
| Key reader 2 | 10 | 2 | 10 | Operator-box key reader for water outlet 1 |
| Display 1 | 10 | - | 1 | Front-panel display for the power-outlet section |
| Temperature sensors 1..2 | 1-wire | 1..2 | - | Cabinet and outdoor temperature |
Layout for WaterStation.
| Connected equipment | Network profile | Slot | Address | Note |
| Energy meter | 1 | 1 | 100 | Internal energy consumption |
| Key readers 1..3 | 10, 10, 11 | 2, 3, 4 | 10, 12, 14 | Operator-box key readers for water outlets 1..3 |
| Displays 1..3 | 10, 10, 11 | - | 11, 13, 15 | Displays for water outlets 1..3 |
| Water meters 1..3 | 14 / 15 / 16 | 1..3 | MBUS | Water outlets 1..3 |
Layout for WaterStation V2.
| Connected equipment | Network profile | Slot | Address | Note |
| Energy meter | 1 | 1 | 1 | Internal energy consumption |
| Key readers 1..3 | 10, 10, 11 | 2, 3, 4 | 10, 12, 14 | Operator-box key readers for water outlets 1..3 |
| Displays 1..3 | 10, 10, 11 | - | 11, 13, 15 | Displays for water outlets 1..3 |
Layout for ShoreSupply. The system supports one HMI and one to three drive lines. Configure the Shore/Grid pair for each drive line with the same slot.
| Connected equipment | Network profile | Slot | Address | Note |
| Pro-face SP5000 HMI | 18 | 1 | 192.168.12.20 | Operator panel for all configured motor-power lines |
| Schneider PM5111 energy meter | 19 | 1 | 100 | ShoreSupply energy measurement over Modbus RTU |
| Room-temperature sensor | 1-Wire | 1 | Serial number | Container temperature |
| Drive line 1 - Shore | 18 | 1 | 192.168.12.30 | Vacon NXL Shore, OPTE1 port 1 (Inverter) |
| Drive line 1 - Grid | 18 | 1 | 192.168.12.31 | Vacon NXL Grid, OPTE1 port 1 (AFE) |
| Drive line 2 - Shore | 18 | 2 | 192.168.12.40 | Vacon NXL Shore, OPTE1 port 1 (Inverter) |
| Drive line 2 - Grid | 18 | 2 | 192.168.12.41 | Vacon NXL Grid, OPTE1 port 1 (AFE) |
| Drive line 3 - Shore | 18 | 3 | 192.168.12.50 | Vacon NXL Shore, OPTE1 port 1 (Inverter) |
| Drive line 3 - Grid | 18 | 3 | 192.168.12.51 | Vacon NXL Grid, OPTE1 port 1 (AFE) |
Layout for OnSiteLight when the installation uses DALI light communication.
| Connected equipment | Network profile | Slot | Address | Note |
| Energy meter 1 | 1 | 1 | 100 | Internal / lighting energy consumption |
| Energy meter 2 | 1 | 2 | 101 | EnergyLogger energy consumption |
| Key reader | 10 | 1 | 0 | Key reader used to operate the light sources |
| Display | 10 | 2 | 2 | Display |
| Modbus to DALI gateway | 2 | - | 131 | Gateway used for light communication |
| DALI light sources | 3 | 1..63 | 1..63 | Repeating light-source layout |
Layout for OnSiteLight when the installation controls light sources directly by digital outputs.
| Connected equipment | Network profile | Slot | Address | Note |
| Energy meter 1 | 1 | 1 | 100 | Lighting energy consumption 1 |
| Energy meter 2 | 1 | 2 | 101 | Lighting energy consumption 2 |
| Energy meter 3 | 1 | 3 | 102 | Lighting energy consumption 4 |
| Energy meter 4 | 1 | 4 | 103 | Lighting energy consumption 3 |
| Key reader | 10 | 1 | 0 | Key reader used to operate the light sources |
| Display | 10 | 2 | 2 | Local display |
| Light source 1 | - | - | DO1, DO2 | Output pair for light 1 |
| Light source 2 | - | - | DO3, DO4 | Output pair for light 2 |
| Light source 3 | - | - | DO5, DO6 | Output pair for light 3 |
| Light source 4 | - | - | DO7, DO8 | Output pair for light 4 |
Layout for GateKeeper with up to six key readers.
| Connected equipment | Network profile | Slot | Address | Note |
| Energy meter | 1 | 1 | 100 | Internal energy consumption |
| Key reader 1 | 10 | 1 | 0 | Operates gate 1 |
| Key reader 2 | 10 | 2 | 1 | Operates gate 1 |
| Key reader 3 | 10 | 3 | 2 | Operates gate 1 |
| Key reader 4 | 10 | 4 | 3 | Operates gate 2 |
| Key reader 5 | 10 | 5 | 4 | Operates gate 2 |
| Key reader 6 | 10 | 6 | 5 | Operates gate 2 |
Layout for Marinella type 1 with VX40.
| Connected equipment | Network profile | Slot | Address | Note |
| Energy meter 1 | 1 | 1 (1) | 100 | Power outlet 1 |
| Energy meter 2 | 1 | 2 (2) | 101 | Power outlet 2 |
| Energy meter 3 | 1 | 3 (3) | 102 | Power outlet 3 |
| Energy meter 4 | 1 | 4 (4) | 103 | Power outlet 4 |
| Energy meter 5 | 1 | 5 (5) | 104 | Power outlet 5 |
| Energy meter 6 | 1 | 6 (6) | 105 | Power outlet 6 |
| Energy meter 7 | 1 | 7 (7) | 106 | Power outlet 7 |
| Energy meter 8 | 1 | 8 (8) | 107 | Power outlet 8 |
| Energy meter 21 | 1 | 21 | 116 | Internal energy consumption |
| Energy meter 22 | 1 | 22 | 115 | External energy consumption, for example video surveillance |
| Key reader 1 | 10 | 1 | 0 | Front-panel key reader for all power outlets |
| Water meter 1 | 14 / 15 / 16 | 1 (9) | - | Water outlet 1 |
Standard layouts for a Marineium with the new LX4 PRO v2 controller. Up to 6 power outlets and up to 12 power outlets are active manufacturing choices. Select the installed Emiko energy meter model on the Device Model page.
| Connected equipment | Network profile | Slot | Address | Note |
| Energy meters 1..12 | 1 | 1..12 | 100..111 | Power outlets 1..12 |
| Key reader 1 | 10 | 1 | 0 | Front-panel Mifare reader |
The installed ADAM modules use fixed vNet positions and node addresses. They are not free DEVADDR# values. See I/O expansion modules for the complete shared mapping.
| Module | vNet position | vNet node | Use |
| ADAM 4069 | Relay output 1 | 61 | Power outlet 1..6 contactors, top light, and water valve |
This documentation-first layout is the governing baseline for the twelve-outlet electrical drawings and ProSoft I/O-profile implementation.
| Module | vNet position | vNet node | Use |
| ADAM 4055 | Digital input/output 1 | 51 | Power outlet 9..14 plug status, internal protection status, water outlet push button, power outlet 9..14 lamps, and provisional power outlet 1..2 contactor drive |
| ADAM 4069 | Relay output 1 | 61 | Power outlet 3..10 contactors |
| ADAM 4069 | Relay output 2 | 63 | Power outlet 11..14 contactors, top light, water outlet lamp, water valve, and one spare relay output |
Layout for OceanWatcher.
| Connected equipment | Network profile | Slot | Address | Note |
| Water velocity instrument | 17 | 1 | 0 | Primary OceanWatcher measurement instrument |