Equipment Defaults

Equipment defaults define the standard DEVMODEL, DEVNETPROFILE, DEVSLOT, and DEVADDR layout for supported Vika equipment.

Use this page when configuring or checking a standard WaterStation, Marinella, OnSiteLight, ServicePedestal, GateKeeper, OceanWatcher, or another documented equipment layout. The configured equipment and its ProSoft implementation must follow the applicable documented default unless an approved project-specific deviation exists.

ServicePedestal

SEPIO-0

Layout for a ServicePedestal with LX4 PRO.

Connected equipment Network profile Slot Address Note
Energy meter 1 1 1 100 Power outlet 1
Energy meter 2 1 2 101 Power outlet 2
Energy meter 3 1 3 102 Power outlet 3
Energy meter 4 1 4 103 Power outlet 4

SEPIO-1

Layout for a ServicePedestal with VX40.

Connected equipment Network profile Slot Address Note
Energy meters 1..15 1 1..15 100..114 Power outlets 1..15
Energy meters 16..21 - - - Reserved
Energy meter 22 1 22 115 EnergyLogger consumption 1
Energy meter 23 1 23 116 Internal energy consumption
Energy meter 24 1 24 117 EnergyLogger consumption 2
Key reader 1 10 1 0 Front-panel key reader for all power outlets
Key reader 2 10 2 10 Operator-box key reader for water outlet 1

SEPIO-2

Layout for a ServicePedestal with IX400.

Connected equipment Network profile Slot Address Note
Energy meters 1..15 1 1..15 100..114 Power outlets 1..15
Energy meters 16..21 - - - Reserved
Energy meter 22 1 22 115 EnergyLogger consumption 1
Energy meter 23 1 23 116 Internal energy consumption
Energy meter 24 1 24 117 EnergyLogger consumption 2
Modbus to M-Bus gateway 3 1 130 Gateway for water-meter communication
Modbus to DALI gateway 3 2 131 Gateway for light communication
Key reader 1 10 1 0 Front-panel key reader for all power outlets
Key reader 2 10 2 10 Operator-box key reader for water outlet 1
Display 1 10 - 1 Front-panel display for the power-outlet section
Temperature sensors 1..2 1-wire 1..2 - Cabinet and outdoor temperature

WaterStation

Layout for WaterStation.

Connected equipment Network profile Slot Address Note
Energy meter 1 1 100 Internal energy consumption
Key readers 1..3 10, 10, 11 2, 3, 4 10, 12, 14 Operator-box key readers for water outlets 1..3
Displays 1..3 10, 10, 11 - 11, 13, 15 Displays for water outlets 1..3
Water meters 1..3 14 / 15 / 16 1..3 MBUS Water outlets 1..3

WaterStation V2

Layout for WaterStation V2.

Connected equipment Network profile Slot Address Note
Energy meter 1 1 1 Internal energy consumption
Key readers 1..3 10, 10, 11 2, 3, 4 10, 12, 14 Operator-box key readers for water outlets 1..3
Displays 1..3 10, 10, 11 - 11, 13, 15 Displays for water outlets 1..3

ShoreSupply

Layout for ShoreSupply. The system supports one HMI and one to three drive lines. Configure the Shore/Grid pair for each drive line with the same slot.

Connected equipment Network profile Slot Address Note
Pro-face SP5000 HMI 18 1 192.168.12.20 Operator panel for all configured motor-power lines
Schneider PM5111 energy meter 19 1 100 ShoreSupply energy measurement over Modbus RTU
Room-temperature sensor 1-Wire 1 Serial number Container temperature
Drive line 1 - Shore 18 1 192.168.12.30 Vacon NXL Shore, OPTE1 port 1 (Inverter)
Drive line 1 - Grid 18 1 192.168.12.31 Vacon NXL Grid, OPTE1 port 1 (AFE)
Drive line 2 - Shore 18 2 192.168.12.40 Vacon NXL Shore, OPTE1 port 1 (Inverter)
Drive line 2 - Grid 18 2 192.168.12.41 Vacon NXL Grid, OPTE1 port 1 (AFE)
Drive line 3 - Shore 18 3 192.168.12.50 Vacon NXL Shore, OPTE1 port 1 (Inverter)
Drive line 3 - Grid 18 3 192.168.12.51 Vacon NXL Grid, OPTE1 port 1 (AFE)

OnSiteLight with DALI

Layout for OnSiteLight when the installation uses DALI light communication.

Connected equipment Network profile Slot Address Note
Energy meter 1 1 1 100 Internal / lighting energy consumption
Energy meter 2 1 2 101 EnergyLogger energy consumption
Key reader 10 1 0 Key reader used to operate the light sources
Display 10 2 2 Display
Modbus to DALI gateway 2 - 131 Gateway used for light communication
DALI light sources 3 1..63 1..63 Repeating light-source layout

OnSiteLight with I/O

Layout for OnSiteLight when the installation controls light sources directly by digital outputs.

Connected equipment Network profile Slot Address Note
Energy meter 111100Lighting energy consumption 1
Energy meter 212101Lighting energy consumption 2
Energy meter 313102Lighting energy consumption 4
Energy meter 414103Lighting energy consumption 3
Key reader1010Key reader used to operate the light sources
Display1022Local display
Light source 1--DO1, DO2Output pair for light 1
Light source 2--DO3, DO4Output pair for light 2
Light source 3--DO5, DO6Output pair for light 3
Light source 4--DO7, DO8Output pair for light 4

GateKeeper

Layout for GateKeeper with up to six key readers.

Connected equipment Network profile Slot Address Note
Energy meter11100Internal energy consumption
Key reader 11010Operates gate 1
Key reader 21021Operates gate 1
Key reader 31032Operates gate 1
Key reader 41043Operates gate 2
Key reader 51054Operates gate 2
Key reader 61065Operates gate 2

Marinella

Layout for Marinella type 1 with VX40.

Connected equipment Network profile Slot Address Note
Energy meter 111 (1)100Power outlet 1
Energy meter 212 (2)101Power outlet 2
Energy meter 313 (3)102Power outlet 3
Energy meter 414 (4)103Power outlet 4
Energy meter 515 (5)104Power outlet 5
Energy meter 616 (6)105Power outlet 6
Energy meter 717 (7)106Power outlet 7
Energy meter 818 (8)107Power outlet 8
Energy meter 21121116Internal energy consumption
Energy meter 22122115External energy consumption, for example video surveillance
Key reader 11010Front-panel key reader for all power outlets
Water meter 114 / 15 / 161 (9)-Water outlet 1

Marineium

Standard layouts for a Marineium with the new LX4 PRO v2 controller. Up to 6 power outlets and up to 12 power outlets are active manufacturing choices. Select the installed Emiko energy meter model on the Device Model page.

Driver Communication

Connected equipment Network profile Slot Address Note
Energy meters 1..12 1 1..12 100..111 Power outlets 1..12
Key reader 1 10 1 0 Front-panel Mifare reader

I/O expansion: Up to 6 power outlets

The installed ADAM modules use fixed vNet positions and node addresses. They are not free DEVADDR# values. See I/O expansion modules for the complete shared mapping.

Module vNet position vNet node Use
ADAM 4069 Relay output 1 61 Power outlet 1..6 contactors, top light, and water valve

I/O expansion: Up to 12 power outlets

This documentation-first layout is the governing baseline for the twelve-outlet electrical drawings and ProSoft I/O-profile implementation.

Module vNet position vNet node Use
ADAM 4055 Digital input/output 1 51 Power outlet 9..14 plug status, internal protection status, water outlet push button, power outlet 9..14 lamps, and provisional power outlet 1..2 contactor drive
ADAM 4069 Relay output 1 61 Power outlet 3..10 contactors
ADAM 4069 Relay output 2 63 Power outlet 11..14 contactors, top light, water outlet lamp, water valve, and one spare relay output

OceanWatcher

Layout for OceanWatcher.

Connected equipment Network profile Slot Address Note
Water velocity instrument1710Primary OceanWatcher measurement instrument

Public revision 21/08/2026