OnSiteLight Parameter Settings

Set parameters for OnSiteLight. Parameters must be set before the system can be put into operation.

Basic Settings

Basic settings for the equipment.

Factory Setup

Load factory settings. All parameters are set to the specified factory settings.

Parameter

Index Range Format Factory setting

Example

OSLFAC -

-

- - OSLFAC

ProgramProgram type installed in the device.

Set which program the equipment must use.

Parameter

Index Range Format Factory setting

Example

OSLPRG - 0..1

0 = Disabled

1 = Standard

0 OSLPRG 1

Access Control

Set how the customer must be validated or whether the equipment is available for free use.

Parameter

Index Range Format Factory setting Example

OSLACC

- 0..3

0 = Blocked (the equipment is blocked and cannot be used)

1 = Free (the equipment is open for free use by everyone, and all consumption is registered to the system accountThe 'Unknown' system account in the customer database is used for consumption from unknown customers or equipment configured for free use.)

2 = Payment (the equipment validates the customer, and only approved customers are accepted)

3 = Mixed (the equipment uses Payment first; if the customer is not validated, Free is used)

2  OSLACC 1

Name

Set the name of the equipment. The name is used, for example, if the equipment sends a messageA message sent by the equipment to one or more configured users, for example an SMS or email alarm..

Parameter

Index Range Format Factory setting Example

OSLNAME

- Max. 20 characters Numbers or letters -  OSLNAME Viking

Greeting

Set a greeting for the equipment. The greeting is used, for example, if the equipment sends a messageA message sent by the equipment to one or more configured users, for example an SMS or email alarm..

Parameter

Index Range Format Factory setting Example
OSLREGARDS - Max. 20 characters Numbers or letters - OSLREGARDS Vikingegaarden

Local Presence

Set whether the user must be on site to operate the equipment.

Parameter

Index Range Format Factory setting Example
OSLLOCCON - 0..1

0 = Local presence required

1 = Local presence not required

0 OSLLOCCON 1

Light Sources

Set parameters for light sources.

Start Timeout

Set the time from when the user presses the start button until the light source must be on. If the time expires, the user approval is cancelled and the user must start again, or another user can use the light source.

Parameter

Index Range Format Factory setting Example
OSLSTARTTIM - 0..6

0 = Function disabled

>0 = Number of minutes (recommended)

2  OSLSTARTTIM 1

End Timeout

Set the time from when the user has turned on the light source until the system turns off the light source or sets the level to minimum lighting or higher. For example, the light source is turned on and the system turns off after 8 hours. This prevents light sources from remaining on if a user forgets to turn them off. In other words, the user is automatically disconnected and light sources are turned off after the specified time.

Parameter

Index Range Format Factory setting Example
OSLSTOPTIM - 0..32000

0 = Function disabled

>0 = Number of hours (recommended)

24  OSLSTOPTIM 48

Lighting Control

Set parameters for how the lighting must operate.

Operating Mode

Set the operating mode for the lighting. Lighting can be controlled manually or set to automatic. In automatic operation, the light turns on shortly before sunset and turns off shortly after sunrise.

Parameter

Index Range Format Factory setting Example
OSLLIGHT - 0..3

0 = Constantly off

1 = Constantly on (turns on to work lighting)

2 = Time controlled (turns on to basic lighting at sunset)

3 = Lux controlled (turns on to basic lighting in darkness according to the selected lux level)

2  OSLLIGHT 1

Location

Set the latitude and longitude for the equipment location used to calculate sunrise and sunset.

Parameter Index Range Format Default Example
LGTLAT - -90000000..90000000 Latitude multiplied by 1,000,000 55900540 LGTLAT 55900540

 

Parameter Index Range Format Default Example
LGTLON - -180000000..180000000 Longitude multiplied by 1,000,000 9393530 LGTLON 9393530

Correction Profile

Select correction profile for time-controlled operation.

Parameter Index Range Format Default Example
LGTOFFSET - -6..6 Offset step 0 LGTOFFSET 1

Lux 

Set the lux count for lux-controlled operation.

Parameter Index Range Format Default Example
LGTLUX - 0..25000

0 = Disabled

>0 = Lux threshold

0 LGTLUX 80

Minimum Lighting

Set the desired level for minimum lighting. For example, the system sets the lighting level to 10% when minimum lighting is activated.

Parameter

Index Range Format Factory setting Example
OSLLUXMIN - 0..100

0 = Off

1..100 corresponds to the desired brightness as a percentage of full brightness

10 OSLLUXMIN 15

Basic Lighting

Set the desired level for basic lighting. For example, the system sets the lighting level to 20% when basic lighting is activated.

Parameter

Index Range Format Factory setting Example
OSLLUXBASIC - 0..100

0 = Off

1..100 corresponds to the desired brightness as a percentage of full brightness

20  OSLLUXBASIC 25

Work Lighting

Set the desired level for work lighting. For example, the system sets the lighting level to 80% when work lighting is activated.

Parameter

Index Range Format Factory setting Example
OSLLUXWORK - 0..100

0 = Off

1..100 corresponds to the desired brightness as a percentage of full brightness

80 OSLLUXWORK 85

Maximum Lighting

Set the desired level for maximum lighting. For example, the system sets the lighting level to 100% when maximum lighting is activated.

Parameter

Index Range Format Factory setting Example
OSLLUXMAX - 0..100

0 = Off

1..100 corresponds to the desired brightness as a percentage, where 100 is full strength

100 OSLLUXMAX 95

Motion Detector

Set parameters for how the motion detector should function.

Motion Detector

Set whether a motion detector is connected to the system. When motion is detected, the system increases the level from minimum lighting to basic lighting for the specified time. For example, when motion is detected, brightness increases from minimum lighting (10%) to basic lighting (20%). After the specified time, for example 20 minutes with no motion detected, brightness is lowered to minimum lighting, which may be set to 10%.

Parameter

Index Range Format Factory setting Example
OSLMOVON - 0..1

0 = No function

1 = Motion detector connected and activated

0 OSLMOVON 1

Sensitivity

Set motion detector sensitivity. The higher the sensitivity, the more motion it detects.

Parameter

Index Range Format Factory setting Example

OSLMOVSEN

- 0..100

0 = Least sensitive

1..100 corresponds to the desired sensitivity as a percentage, where 100 is most sensitive

50 OSLMOVSEN 60

Light Time

Set how long the system waits after detected motion before regulating brightness back to minimum lighting.

Parameter

Index Range Format Factory setting Example
OSLMOVTIM - 1..120 Minutes 20  OSLMOVTIM 25

Order Number

Set parameters for handling order numberOrder number from an ERP system or similar source, used as a reference to the customer order.. When this function is used, the user can enter an order numberOrder number from an ERP system or similar source, used as a reference to the customer order., which is registered together with the energy consumption. When the user calls the equipment, an SMSSMS is a text message that can be sent or received with a mobile phone. is sent to the user. The user must reply with the desired order numberOrder number from an ERP system or similar source, used as a reference to the customer order.. When the equipment receives the SMSSMS is a text message that can be sent or received with a mobile phone. with the order numberOrder number from an ERP system or similar source, used as a reference to the customer order., the lamp is switched on.

Response Time

Set the time from when the user receives an SMSSMS is a text message that can be sent or received with a mobile phone. until the user must reply with an order numberOrder number from an ERP system or similar source, used as a reference to the customer order.. If the user does not reply before the time expires, the user must, for example, call again and a new SMSSMS is a text message that can be sent or received with a mobile phone. is sent.

Parameter

Index Range Format Factory setting Example
OSLORDTIM - 1..8 Minutes 2 OSLORDTIM 3

SMSSMS is a text message that can be sent or received with a mobile phone. type

Set how SMSSMS is a text message that can be sent or received with a mobile phone. messages are displayed on the recipient's phone. An SMSSMS is a text message that can be sent or received with a mobile phone. can be shown as a standard SMSSMS is a text message that can be sent or received with a mobile phone. or as an SMSSMS is a text message that can be sent or received with a mobile phone. that is displayed on the screen in a new window for a more visible presentation. The downside of a displayed SMSSMS is a text message that can be sent or received with a mobile phone. is that it disappears again and must be found among standard SMSSMS is a text message that can be sent or received with a mobile phone. messages when it needs to be answered.

Parameter

Index Range Format Factory setting Example
OSLUSEFLASH - 0..1

0 = Standard SMSSMS is a text message that can be sent or received with a mobile phone. (recommended)

1 = Shown SMSSMS is a text message that can be sent or received with a mobile phone.

0 OSLUSEFLASH 1

 

 

 

 

 

 

 

 