Set parameters for OnSiteLight. Parameters must be set before the system can be put into operation.
Basic settings for the equipment.
Load factory settings. All parameters are set to the specified factory settings.
|
Parameter |
Index | Range | Format | Factory setting |
Example |
| OSLFAC | - |
- |
- | - | OSLFAC |
Set which program the equipment must use.
|
Parameter |
Index | Range | Format | Factory setting |
Example |
| OSLPRG | - | 0..1 |
0 = Disabled 1 = Standard |
0 | OSLPRG 1 |
Set how the customer must be validated or whether the equipment is available for free use.
|
Parameter |
Index | Range | Format | Factory setting | Example |
| - | 0..3 |
0 = Blocked (the equipment is blocked and cannot be used) 1 = Free (the equipment is open for free use by everyone, and all consumption is registered to the system account) 2 = Payment (the equipment validates the customer, and only approved customers are accepted) 3 = Mixed (the equipment uses Payment first; if the customer is not validated, Free is used) |
2 | OSLACC 1 |
Set the name of the equipment. The name is used, for example, if the equipment sends a message.
|
Parameter |
Index | Range | Format | Factory setting | Example |
| - | Max. 20 characters | Numbers or letters | - | OSLNAME Viking |
Set a greeting for the equipment. The greeting is used, for example, if the equipment sends a message.
|
Parameter |
Index | Range | Format | Factory setting | Example |
| OSLREGARDS | - | Max. 20 characters | Numbers or letters | - | OSLREGARDS Vikingegaarden |
Set whether the user must be on site to operate the equipment.
If local presence is disabled, the user can operate the equipment, for example from home
Note relevant legislation about remote operation of equipment
|
Parameter |
Index | Range | Format | Factory setting | Example |
| OSLLOCCON | - | 0..1 |
0 = Local presence required 1 = Local presence not required |
0 | OSLLOCCON 1 |
Set parameters for light sources.
Set the time from when the user presses the start button until the light source must be on. If the time expires, the user approval is cancelled and the user must start again, or another user can use the light source.
|
Parameter |
Index | Range | Format | Factory setting | Example |
| OSLSTARTTIM | - | 0..6 |
0 = Function disabled >0 = Number of minutes (recommended) |
2 | OSLSTARTTIM 1 |
Set the time from when the user has turned on the light source until the system turns off the light source or sets the level to minimum lighting or higher. For example, the light source is turned on and the system turns off after 8 hours. This prevents light sources from remaining on if a user forgets to turn them off. In other words, the user is automatically disconnected and light sources are turned off after the specified time.
|
Parameter |
Index | Range | Format | Factory setting | Example |
| OSLSTOPTIM | - | 0..32000 |
0 = Function disabled >0 = Number of hours (recommended) |
24 | OSLSTOPTIM 48 |
Set parameters for how the lighting must operate.
Set the operating mode for the lighting. Lighting can be controlled manually or set to automatic. In automatic operation, the light turns on shortly before sunset and turns off shortly after sunrise.
When automatic mode is selected, lamps can always be overridden, for example from a push button
Note that time-controlled operation is used as backup for lux-controlled operation in case of errors
|
Parameter |
Index | Range | Format | Factory setting | Example |
| OSLLIGHT | - | 0..3 |
0 = Constantly off 1 = Constantly on (turns on to work lighting) 2 = Time controlled (turns on to basic lighting at sunset) 3 = Lux controlled (turns on to basic lighting in darkness according to the selected lux level) |
2 | OSLLIGHT 1 |
Set the latitude and longitude for the equipment location used to calculate sunrise and sunset.
| Parameter | Index | Range | Format | Default | Example |
LGTLAT |
- | -90000000..90000000 | Latitude multiplied by 1,000,000 | 55900540 | LGTLAT 55900540 |
| Parameter | Index | Range | Format | Default | Example |
LGTLON |
- | -180000000..180000000 | Longitude multiplied by 1,000,000 | 9393530 | LGTLON 9393530 |
Select correction profile for time-controlled operation.
| Parameter | Index | Range | Format | Default | Example |
LGTOFFSET |
- | -6..6 | Offset step | 0 | LGTOFFSET 1 |
Set the lux count for lux-controlled operation.
| Parameter | Index | Range | Format | Default | Example |
LGTLUX |
- | 0..25000 |
0 = Disabled >0 = Lux threshold |
0 | LGTLUX 80 |
Set the desired level for minimum lighting. For example, the system sets the lighting level to 10% when minimum lighting is activated.
|
Parameter |
Index | Range | Format | Factory setting | Example |
| OSLLUXMIN | - | 0..100 |
0 = Off 1..100 corresponds to the desired brightness as a percentage of full brightness |
10 | OSLLUXMIN 15 |
Set the desired level for basic lighting. For example, the system sets the lighting level to 20% when basic lighting is activated.
|
Parameter |
Index | Range | Format | Factory setting | Example |
| OSLLUXBASIC | - | 0..100 |
0 = Off 1..100 corresponds to the desired brightness as a percentage of full brightness |
20 | OSLLUXBASIC 25 |
Set the desired level for work lighting. For example, the system sets the lighting level to 80% when work lighting is activated.
|
Parameter |
Index | Range | Format | Factory setting | Example |
| OSLLUXWORK | - | 0..100 |
0 = Off 1..100 corresponds to the desired brightness as a percentage of full brightness |
80 | OSLLUXWORK 85 |
Set the desired level for maximum lighting. For example, the system sets the lighting level to 100% when maximum lighting is activated.
|
Parameter |
Index | Range | Format | Factory setting | Example |
| OSLLUXMAX | - | 0..100 |
0 = Off 1..100 corresponds to the desired brightness as a percentage, where 100 is full strength |
100 | OSLLUXMAX 95 |
Set parameters for how the motion detector should function.
Set whether a motion detector is connected to the system. When motion is detected, the system increases the level from minimum lighting to basic lighting for the specified time. For example, when motion is detected, brightness increases from minimum lighting (10%) to basic lighting (20%). After the specified time, for example 20 minutes with no motion detected, brightness is lowered to minimum lighting, which may be set to 10%.
|
Parameter |
Index | Range | Format | Factory setting | Example |
| OSLMOVON | - | 0..1 |
0 = No function 1 = Motion detector connected and activated |
0 | OSLMOVON 1 |
Set motion detector sensitivity. The higher the sensitivity, the more motion it detects.
|
Parameter |
Index | Range | Format | Factory setting | Example |
| - | 0..100 |
0 = Least sensitive 1..100 corresponds to the desired sensitivity as a percentage, where 100 is most sensitive |
50 | OSLMOVSEN 60 |
Set how long the system waits after detected motion before regulating brightness back to minimum lighting.
|
Parameter |
Index | Range | Format | Factory setting | Example |
| OSLMOVTIM | - | 1..120 | Minutes | 20 | OSLMOVTIM 25 |
Set parameters for handling order number. When this function is used, the user can enter an order number, which is registered together with the energy consumption. When the user calls the equipment, an SMS is sent to the user. The user must reply with the desired order number. When the equipment receives the SMS with the order number, the lamp is switched on.
Set the time from when the user receives an SMS until the user must reply with an order number. If the user does not reply before the time expires, the user must, for example, call again and a new SMS is sent.
|
Parameter |
Index | Range | Format | Factory setting | Example |
| OSLORDTIM | - | 1..8 | Minutes | 2 | OSLORDTIM 3 |
Set how SMS messages are displayed on the recipient's phone. An SMS can be shown as a standard SMS or as an SMS that is displayed on the screen in a new window for a more visible presentation. The downside of a displayed SMS is that it disappears again and must be found among standard SMS messages when it needs to be answered.
|
Parameter |
Index | Range | Format | Factory setting | Example |
| OSLUSEFLASH | - | 0..1 |
0 = Standard SMS (recommended) 1 = Shown SMS |
0 | OSLUSEFLASH 1 |