Device Model Communication Setup

Use this reference to configure a driver profile for a supported external meter, reader, sensor, gateway, drive, HMI, light controller, or signalling device.

Each row shows the model code and the related communication settings normally needed for one configured profile.

How To Read The Tables

The tables use public profile numbers. Select DEVNETPROFILE# from the Network Profiles page when port, serial settings, protocol family, or alternative profiles must be confirmed. See Instrument Defaults before using factory address, baud rate, or serial format values during commissioning.

Default means the standard setup choice shown in this reference. For RS485 devices, choose the default profile for the installed port.

Auto means the driver is not forced to one specific product model. Use Auto for normal setup when the driver can select or identify the supported model path. Select a specific model only when the installation must explicitly use that model.

DEVADDR# means the address value used by the selected communication path. For Modbus RTU, it is the Modbus address.

DEVSLOT# entries such as Energy meter slot or Water meter slot name the slot family. Enter the numeric slot for that family in Driver Communication Settings. Slot numbering starts at 1 for the first configured item in the family unless a standard Communication Profiles layout shows a specific slot mapping.

Auto Entries

DEVMODEL# Device / model Communication path DEVNETPROFILE# DEVGWPROFILE# DEVADDR# DEVSLOT# DEVON#
100xxxxxxAuto or unused model typeNo specific driver model selected-0--0
101999xxxAny manufacturer - energy pulse counterPulse or digital counter120Counter input or indexEnergy counter slot1
102999xxxAny manufacturer - heat pulse counterPulse or digital counter120Counter input or indexHeat counter slot1
103999xxxAny manufacturer - water pulse counterPulse or digital counter120Counter input or indexWater counter slot1

Energy Meters

For Carlo Gavazzi, Janitza, and Emiko Modbus RTU energy meters, use Auto for normal setup when available. During initialization, the driver identifies supported connected meters and then uses the detected model-specific read path. A matching specific model and Auto use the same output and read path after successful initialization; the specific code documents or constrains the intended meter model.

DEVMODEL# Device / model Communication path DEVNETPROFILE# DEVGWPROFILE# DEVADDR# DEVSLOT# DEVON#
101101100Carlo Gavazzi - AutoModbus RTUDefault: 1/20Modbus addressEnergy meter slot1
101101101Carlo Gavazzi - EM23Modbus RTUDefault: 1/20Modbus addressEnergy meter slot1
101101102Carlo Gavazzi - EM24Modbus RTU or wireless M-BusDefault: 1/20Modbus or meter addressEnergy meter slot1
101101103Carlo Gavazzi - EM33Modbus RTUDefault: 1/20Modbus addressEnergy meter slot1
101101104Carlo Gavazzi - EM111Modbus RTUDefault: 1/20Modbus addressEnergy meter slot1
101101106Carlo Gavazzi - EM340Modbus RTUDefault: 1/20Modbus addressEnergy meter slot1
101101107Carlo Gavazzi - EM210Modbus RTUDefault: 1/20Modbus addressEnergy meter slot1
101101108Carlo Gavazzi - EM330Modbus RTUDefault: 1/20Modbus addressEnergy meter slot1
101101109Carlo Gavazzi - EM110Modbus RTUDefault: 1/20Modbus addressEnergy meter slot1
101101110Carlo Gavazzi - EM112Modbus RTUDefault: 1/20Modbus addressEnergy meter slot1
101101111Carlo Gavazzi - EM24WWireless M-Bus or Modbus RTUWireless M-Bus: 9; Modbus RTU default: 1/20Meter or Modbus addressEnergy meter slot1
101101112Carlo Gavazzi - EM530Modbus RTUDefault: 1/20Modbus addressEnergy meter slot1
101101114Carlo Gavazzi - EM540Modbus RTUDefault: 1/20Modbus addressEnergy meter slot1
101101115Carlo Gavazzi - WM30Modbus RTUDefault: 1/20Modbus addressEnergy meter slot1
101101116Carlo Gavazzi - WM40Modbus RTUDefault: 1/20Modbus addressEnergy meter slot1
101101117Carlo Gavazzi - EM511Modbus RTUDefault: 1/20Modbus addressEnergy meter slot1
101105101Schneider - PM5111Modbus RTU1-8, 19-200Modbus addressEnergy meter slot1
101108101Orno - OR-WE-516Pulse or Modbus RTU12 or 1-8/19-200Counter input or Modbus addressEnergy meter slot1
101108102Orno - OR-WE-525Pulse or Modbus RTU12 or 1-8/19-200Counter input or Modbus addressEnergy meter slot1
101112100Janitza - AutoModbus RTU1-8, 19-200Modbus addressEnergy meter slot1
101112101Janitza - standardModbus RTU1-8, 19-200Modbus addressEnergy meter slot1
101114100Emiko - AutoModbus RTUDefault: 3/40Modbus addressEnergy meter slot1
101114101Emiko - EMI511Modbus RTUDefault: 3/40Modbus addressEnergy meter slot1
101114102Emiko - EMI530Modbus RTUDefault: 3/40Modbus addressEnergy meter slot1
101114103Emiko - EMI540Modbus RTUDefault: 3/40Modbus addressEnergy meter slot1

Heat Meters

Select the listed heat meter model or the pulse counter path that matches the installation. The heat pulse counter wildcard in Auto Entries is a pulse or digital counter path, not model detection.

DEVMODEL# Device / model Communication path DEVNETPROFILE# DEVGWPROFILE# DEVADDR# DEVSLOT# DEVON#
102102101Kamstrup - MULTICAL 302Wireless M-Bus or Modbus RTU9 or 1-8/19-200Meter or Modbus addressHeat meter slot1
102102102Kamstrup - MULTICAL 602Modbus RTU, wired M-Bus, or wireless M-Bus1-8, 9, 14-16, 19-200 or 4Modbus or M-Bus addressHeat meter slot1
102102103Kamstrup - MULTICAL 303Wireless M-Bus or Modbus RTU9 or 1-8/19-200Meter or Modbus addressHeat meter slot1
102102104Kamstrup - MULTICAL 402Modbus RTU, wired M-Bus, or wireless M-Bus1-8, 9, 14-16, 19-200Modbus or M-Bus addressHeat meter slot1
102102105Kamstrup - MULTICAL 403Wireless M-Bus or Modbus RTU9 or 1-8/19-200Meter or Modbus addressHeat meter slot1
102102106Kamstrup - MULTICAL 603Modbus RTU, wired M-Bus, or wireless M-Bus1-8, 9, 14-16, 19-200Modbus or M-Bus addressHeat meter slot1
102102108Kamstrup - MULTICAL 803Modbus RTU, wired M-Bus, or wireless M-Bus1-8, 9, 14-16, 19-200Modbus or M-Bus addressHeat meter slot1
102102109Kamstrup - MULTICAL 801Modbus RTU, wired M-Bus, or wireless M-Bus1-8, 9, 14-16, 19-200Modbus or M-Bus addressHeat meter slot1
102102110Kamstrup - MULTICAL 802Modbus RTU, wired M-Bus, or wireless M-Bus1-8, 9, 14-16, 19-200Modbus or M-Bus addressHeat meter slot1

Water Meters

Select the listed water meter model or the pulse counter path that matches the installation. The water pulse counter wildcard in Auto Entries is a pulse or digital counter path, not model detection.

DEVMODEL# Device / model Communication path DEVNETPROFILE# DEVGWPROFILE# DEVADDR# DEVSLOT# DEVON#
103102101Kamstrup - MULTICAL 61Modbus RTU1-8, 19-200Modbus addressWater meter slot1
103102102Kamstrup - MULTICAL 62Modbus RTU or gateway M-Bus1-8, 19-200 or 3Modbus or M-Bus addressWater meter slot1
103102103Kamstrup - MULTICAL 21Modbus RTU, wired M-Bus, or wireless M-Bus1-8, 9, 14-16, 19-200Modbus or M-Bus addressWater meter slot1
103102104Kamstrup - flowIQ 2200Wireless M-Bus or Modbus RTU9 or 1-8/19-200Meter or Modbus addressWater meter slot1
103102105Kamstrup - flowIQ 3100Modbus RTU, wired M-Bus, or wireless M-Bus1-8, 9, 14-16, 19-200Modbus or M-Bus addressWater meter slot1
103102106Kamstrup - flowIQ 3200Wireless M-Bus or Modbus RTU9 or 1-8/19-200Meter or Modbus addressWater meter slot1
103102107Kamstrup - flowIQ GatewayModbus RTU, wired M-Bus, or wireless M-Bus1-8, 9, 14-16, 19-200Modbus or M-Bus addressWater meter slot1
103102108Kamstrup - flowIQ 2101Modbus RTU, wired M-Bus, or wireless M-Bus1-8, 9, 14-16, 19-200Modbus or M-Bus addressWater meter slot1
103102109Kamstrup - MULTICAL 603 as water meterModbus RTU, wired M-Bus, or wireless M-Bus1-8, 9, 14-16, 19-200Modbus or M-Bus addressWater meter slot1
103103101Sensus - HRI-B4Wired M-Bus or M-Bus through gateway14-16 or Modbus RTU profile to gateway0 or 1M-Bus meter addressWater meter slot1
103103102Sensus - HRI-Mei-B4Wired M-Bus or M-Bus through gateway14-16 or Modbus RTU profile to gateway0 or 1M-Bus meter addressWater meter slot1
103103103Sensus - iPERLWireless M-Bus90Wireless M-Bus meter address or idWater meter slot1
103113101Comac Cal - Flow 38Modbus RTU1-8, 19-200Modbus addressWater meter slot1

Key Readers And Displays

DEVMODEL# Device / model Communication path DEVNETPROFILE# DEVGWPROFILE# DEVADDR# DEVSLOT# DEVON#
104104100Conlan / aKey - AutoOSDP over RS48510 or 110OSDP addressKey reader or display slot1
104104101Conlan - KeyPadOSDP over RS48510 or 110OSDP addressKey reader slot1
104104102Conlan - KeyPad Bluetooth variantOSDP over RS48510 or 110OSDP addressKey reader slot1
104104103Conlan - KeyReaderOSDP over RS48510 or 110OSDP addressKey reader slot1
104104104Conlan - display or key-reader variantOSDP over RS48510 or 110OSDP addressDisplay or key-reader slot1

DALI And Light Control

DEVMODEL# Device / model Communication path DEVNETPROFILE# DEVGWPROFILE# DEVADDR# DEVSLOT# DEVON#
105106100DALI - AutoModbus RTU to DALI gateway1-8, 19-202 when gateway is usedDALI address or channel behind gatewayDALI light-control slot1
105106xxxDALI - fallback model valuesModbus RTU to DALI gateway1-8, 19-202 when gateway is usedDALI address or channel behind gatewayDALI light-control slot1

Velocity And Flow Devices

DEVMODEL# Device / model Communication path DEVNETPROFILE# DEVGWPROFILE# DEVADDR# DEVSLOT# DEVON#
106107100Argonaut SonTek - AutoRS232 serial170Serial or device address if usedVelocity or flow slot1
106107101Argonaut SonTek - SL500RS232 serial170Serial or device address if usedVelocity or flow slot1

Climate And Level Sensors

For Thies Clima, Auto identifies supported Hydro Termo Baro variants and then uses the detected model path. For GILL MaxiMet and OTT CBS, Auto selects the family's standard supported path. Siemens Auto is a Siemens family path; use the SITRANS LR110 or SITRANS LR120 row when the model is known.

DEVMODEL# Device / model Communication path DEVNETPROFILE# DEVGWPROFILE# DEVADDR# DEVSLOT# DEVON#
107109100Thies Clima - AutoModbus RTU1-8, 19-200Modbus addressClimate/level sensor slot1
107109101Thies Clima - Hydro Termo Baro 1.1006.54.081Modbus RTU1-8, 19-200Modbus addressClimate/level sensor slot1
107109102Thies Clima - WSC10Modbus RTU1-8, 19-200Modbus addressClimate/level sensor slot1
107109103Thies Clima - WSC11Modbus RTU1-8, 19-200Modbus addressClimate/level sensor slot1
107110100GILL MaxiMet - AutoModbus RTU1-8, 19-200Modbus addressClimate/level sensor slot1
107110101GILL MaxiMet - GMX600Modbus RTU1-8, 19-200Modbus addressClimate/level sensor slot1
107111100OTT CBS - AutoModbus RTU1-8, 19-200Modbus addressClimate/level sensor slot1
107111101OTT CBS - Bubble SensorModbus RTU1-8, 19-200Modbus addressClimate/level sensor slot1
107116100Siemens - AutoModbus RTU when the Siemens LR1x0 driver path is used1-8, 19-200Modbus addressClimate/level sensor slot1
107116101Siemens - SITRANS LR110Modbus RTUSelected from the RS485 Modbus RTU profiles matching port and serial settings0Modbus addressLogical climate/level sensor slot1
107116102Siemens - SITRANS LR120Modbus RTU1-8, 19-200Modbus addressClimate/level sensor slot1
107999101Any manufacturer - analog inputAnalog input through the product IO listProduct IO list, not a standard network profile0Analog input or channel from the product IO listProduct IO list1 when used

VSD And HMI

DEVMODEL# Device / model Communication path DEVNETPROFILE# DEVGWPROFILE# DEVADDR# DEVSLOT# DEVON#
108114100Danfoss - AutoLegacy VSD communication pathUse the product setup0Address used by the selected pathVSD slot1
108114101Danfoss - Vacon NXL ShoreModbus TCP/IP180TCP/IP unit or address contextVSD slot1
108114102Danfoss - Vacon NXL GridModbus TCP/IP180TCP/IP unit or address contextVSD slot1
109115100Proface - AutoModbus TCP/IP180TCP/IP unit or address contextHMI slot1
109115101Proface - SP5000Modbus TCP/IP180TCP/IP unit or address contextHMI slot1

Maritime Signalling

DEVMODEL# Device / model Communication path DEVNETPROFILE# DEVGWPROFILE# DEVADDR# DEVSLOT# DEVON#
110117101MSM - MCL360Modbus RTU1-8, 19-200Modbus addressSignalling slot1
110117102MSM - MBL-series MF12Modbus RTU1-8, 19-200Modbus addressSignalling slot1
110117103MSM - MBR-series PPC02Modbus RTU1-8, 19-200Modbus addressSignalling slot1
110118101Tideland - MaxiHalo-60 or Nova-65 with Halo2 ControllerModbus RTU1-8, 19-200Modbus addressSignalling slot1
110118102Tideland - Rotator with MaxiHalo60 and Halo2 ControllerModbus RTU1-8, 19-200Modbus addressSignalling slot1
110118103Tideland - SolaMax with Halo2 ControllerModbus RTU1-8, 19-200Modbus addressSignalling slot1
110118104Tideland - Flasher with MaxiHALO-60 II ControllerModbus RTU1-8, 19-200Modbus addressSignalling slot1
110118105Tideland - Rotator with MaxiHALO-60 II ControllerModbus RTU1-8, 19-200Modbus addressSignalling slot1
110118106Tideland - Quad Controller Lights, Nova-250, MaxLED-180, MasterRangeModbus RTU1-8, 19-200Modbus addressSignalling slot1
110118107Tideland - NOVA-65 ES-1071 non-solarModbus RTU1-8, 19-200Modbus addressSignalling slot1
110118108Tideland - NOVA-65 ES-1071 solarModbus RTU1-8, 19-200Modbus addressSignalling slot1