Yes means the model can be used with that communication path.
A dash (-) means that communication path is not used for that model.
Energy Meters
Supported energy-meter models and their communication paths.
Manufacturer
Model
Pulse
Wireless M-Bus
Wired M-Bus
Modbus RS485
Notes
Carlo Gavazzi
EM111
Yes
-
-
Yes
Dedicated model entry.
EM23
Yes
-
-
Yes
Dedicated model entry.
EM24
Yes
-
-
Yes
Dedicated model entry.
EM24W
-
Yes
-
-
Wireless M-Bus variant.
EM33
Yes
-
-
Yes
Dedicated model entry.
EM210
Yes
-
-
Yes
Dedicated model entry.
EM330
Yes
-
-
Yes
Dedicated model entry.
EM340
Yes
-
-
Yes
Dedicated model entry.
EM530
Yes
-
-
Yes
Dedicated model entry.
EM540
Yes
-
-
Yes
Dedicated model entry.
WM30
-
-
-
Yes
Energy-meter family.
WM40
-
-
-
Yes
Energy-meter family.
Orno
OR-WE-516
Yes
-
-
Yes
Dedicated model entry.
OR-WE-525
Yes
-
-
Yes
Dedicated model entry.
Janitza
Janitza auto
-
-
-
Yes
Auto path checks for a supported Janitza meter.
Janitza standard
-
-
-
Yes
Specific Janitza standard model.
EMIKO
Generic / auto
-
-
-
Yes
Generic EMIKO meter profile.
EMI511
-
-
-
Yes
Dedicated EMIKO model.
EMI530
-
-
-
Yes
Dedicated EMIKO model.
EMI540
-
-
-
Yes
Dedicated EMIKO model.
Any manufacturer
Pulse counter
Yes
-
-
-
Use when the installation exposes only a pulse output.
Heat Meters
Supported heat-meter models and their communication paths.
Manufacturer
Model
Pulse
Wireless M-Bus
Wired M-Bus
Modbus RS485
Notes
Kamstrup
MULTICAL 302
-
Yes
Yes
-
Heat-meter model.
MULTICAL 303
-
Yes
-
-
Wireless M-Bus.
MULTICAL 402
-
Yes
Yes
-
Wired and wireless M-Bus.
MULTICAL 403
-
Yes
-
-
Wireless M-Bus.
MULTICAL 602
-
Yes
Yes
-
Wired and wireless M-Bus.
MULTICAL 603
-
Yes
Yes
-
Wired and wireless M-Bus.
MULTICAL 801
-
Yes
Yes
-
Wired and wireless M-Bus.
MULTICAL 802
-
Yes
Yes
-
Wired and wireless M-Bus.
MULTICAL 803
-
Yes
Yes
-
Wired and wireless M-Bus.
Any manufacturer
Pulse counter
Yes
-
-
-
Use when the installation exposes only a pulse output.
Water Meters
Supported water-meter models and their communication paths.
Manufacturer
Model
Pulse
Wireless M-Bus
Wired M-Bus
Modbus RS485
Notes
Kamstrup
MULTICAL 21
-
Yes
Yes
-
Water-meter model.
MULTICAL 61
-
-
-
Yes
Dedicated model entry.
MULTICAL 62
-
-
-
Yes
Dedicated model entry.
flowIQ 2200
-
Yes
-
-
Wireless M-Bus variant.
flowIQ 3100
-
Yes
Yes
-
Wired and wireless M-Bus.
flowIQ 3200
-
Yes
-
-
Wireless M-Bus variant.
flowIQ Gateway
Yes
Yes
Yes
Yes
Gateway model.
MULTICAL 603 as water meter
-
Yes
Yes
-
Water-meter variant.
Sensus
HRI-B4
Yes
-
Yes
-
Water-meter model.
HRI-Mei B4
Yes
-
Yes
-
Water-meter model.
iPERL
-
Yes
-
-
Wireless M-Bus variant.
Comac Cal
Flow 38
-
-
-
Yes
Water-meter model.
Any manufacturer
Pulse counter
Yes
-
-
-
Use when the installation exposes only a pulse output.
Key Readers
Models
Path
Notes
Conlan / aKey generic profile
OSDP over RS485
Typical setup uses network profile 10 and slot positions 1..6.
Light
Models
Path
Notes
DALI generic profile
Gateway-based Modbus to DALI
Use with gateway profile 2 when communication goes through a Modbus-to-DALI converter.
Velocity
Models
Path
Notes
SonTek SL500
Dedicated serial path
Water velocity and flow device family.
Climate & Level
Manufacturer
Models
Path
Notes
Thies Clima
Hydro Termo Baro / ADM, WSC10, WSC11
Dedicated serial path
Auto detects supported Hydro Termo Baro variants.
GILL
MaxiMet GMX600
Dedicated serial path
Compact weather station family.
OTT
CBS Bubble Sensor
Dedicated serial path
Water level by bubble sensor principle.
Siemens
SITRANS LR110, SITRANS LR120
Dedicated serial path
Radar level sensors.
Any manufacturer
Analog input
Analog input
Use with a validated analog input setup.
VSD & HMI
Models
Path
Notes
Vacon NXL Shore, Vacon NXL Grid
Dedicated serial path
Variable speed drive models.
Proface SP5000
Dedicated serial path
HMI model.
Maritime
Models
Path
Notes
MSM MCL360, MBL-series, MBR-series
Dedicated serial path
Maritime signalling family.
Tideland Halo / Nova controller variants
Dedicated serial path
Tideland maritime signalling variants.
Public revision 21/05/2026
Cookies on Vika Help
Vika Help uses necessary browser storage and, if you allow it, statistics cookies for Google Analytics. You can accept all, reject all, or open settings.
Cookie settings
Choose which categories may be used on Vika Help.
NecessaryAlways on. Required to remember your consent choice and keep the documentation shell working as intended.
Allows Google Analytics to measure aggregate use of the documentation site.