Field Instrument Guide
Use this guide to select field instruments that are validated for Vikingegaarden equipment and Emiko logging.
For predictable commissioning and support, use instruments supplied or specified as part of the Vikingegaarden solution. Other instruments may need validation before they can be connected, scaled, logged, or supported.
Use DEVMODEL# for serial/driver devices and the product IO list for analog, digital, and 1-Wire instruments. Use Instrument Defaults when factory address, baud rate, or serial format values are needed during commissioning.
Connection paths
Path
Typical instruments
Where to continue
Serial / driver device
Serial, Modbus, M-Bus, wireless M-Bus, and other supported driver devices.
Use Device Model Setup , Instrument Defaults , DEVMODEL# , Network Profiles , and Gateway Profiles .
Analog input
4-20 mA and 0-10 V transmitters.
Use the product IO list and Analog Transmitter Wiring .
Digital input / counter
Pulse instruments such as rain gauges, meter pulses, and other count inputs.
Use the product IO list. Detailed DI/counter setup pages will be expanded as the setup path is released.
1-Wire
Simple temperature sensors, for example soil temperature.
Use 1-Wire Temperature and the product IO list.
Energy meters
Device
DEVMODEL#
Connection path
Purpose
Notes
EMIKO - EMI511
101114101
RS485 Modbus RTU
Energy registration in Emiko installations.
-
EMIKO - EMI530
101114102
RS485 Modbus RTU
CT-based pump or equipment energy registration.
-
EMIKO - EMI540
101114103
RS485 Modbus RTU
Direct-connected pump or equipment energy registration.
-
Carlo Gavazzi - EM511
101101117
RS485 Modbus RTU
Energy registration with the equivalent supported model.
Supported equivalent.
Carlo Gavazzi - EM530
101101112
RS485 Modbus RTU
CT-based energy registration with the equivalent supported model.
Supported equivalent.
Carlo Gavazzi - EM540
101101114
RS485 Modbus RTU
Direct-connected energy registration with the equivalent supported model.
Supported equivalent.
Carlo Gavazzi - EM23
101101101
RS485 Modbus RTU
Energy registration.
-
Carlo Gavazzi - EM24
101101102
RS485 Modbus RTU
Energy registration.
-
Carlo Gavazzi - EM33
101101103
RS485 Modbus RTU
Energy registration.
-
Carlo Gavazzi - EM111
101101104
RS485 Modbus RTU
Energy registration.
-
Carlo Gavazzi - EM340
101101106
RS485 Modbus RTU
Energy registration.
-
Carlo Gavazzi - EM210
101101107
RS485 Modbus RTU
Energy registration.
-
Carlo Gavazzi - EM330
101101108
RS485 Modbus RTU
Energy registration.
-
Carlo Gavazzi - EM110
101101109
RS485 Modbus RTU
Energy registration.
-
Carlo Gavazzi - EM112
101101110
RS485 Modbus RTU
Energy registration.
-
Carlo Gavazzi - EM24W
101101111
Wireless M-Bus
Wireless energy registration.
-
Carlo Gavazzi - WM30
101101115
RS485 Modbus RTU
Energy registration.
-
Carlo Gavazzi - WM40
101101116
RS485 Modbus RTU
Energy registration.
-
Orno - OR-WE-516
101108101
Pulse or RS485 Modbus RTU
Energy registration.
-
Orno - OR-WE-525
101108102
Pulse or RS485 Modbus RTU
Energy registration.
-
Janitza - Auto
101112100
RS485 Modbus RTU
Energy registration.
Auto checks for a supported Janitza meter before using the Janitza read path.
Janitza - standard
101112101
RS485 Modbus RTU
Energy registration.
Specific Janitza standard model.
Heat meters
Device
DEVMODEL#
Connection path
Purpose
Notes
Kamstrup - MULTICAL 302 102102101Wireless or wired M-Bus Heat and thermal energy registration. -
Kamstrup - MULTICAL 602 102102102Wireless or wired M-Bus Heat and thermal energy registration. -
Kamstrup - MULTICAL 303 102102103Wireless M-Bus Heat and thermal energy registration. -
Kamstrup - MULTICAL 402 102102104Wireless or wired M-Bus Heat and thermal energy registration. -
Kamstrup - MULTICAL 403 102102105Wireless M-Bus Heat and thermal energy registration. -
Kamstrup - MULTICAL 603 102102106Wireless or wired M-Bus Heat and thermal energy registration. -
Kamstrup - MULTICAL 803 102102108Wireless or wired M-Bus Heat and thermal energy registration. -
Kamstrup - MULTICAL 801 102102109Wireless or wired M-Bus Heat and thermal energy registration. -
Kamstrup - MULTICAL 802 102102110Wireless or wired M-Bus Heat and thermal energy registration. -
Water meters
Device
DEVMODEL#
Connection path
Purpose
Notes
Kamstrup - MULTICAL 61 103102101RS485 Modbus RTU Water consumption registration. -
Kamstrup - MULTICAL 62 103102102RS485 Modbus RTU Water consumption registration. -
Kamstrup - MULTICAL 21 103102103Wireless or wired M-Bus Water consumption registration. -
Kamstrup - flowIQ 2200 103102104Wireless M-Bus Water consumption registration. -
Kamstrup - flowIQ 3100 103102105Wireless M-Bus Water consumption registration. -
Kamstrup - flowIQ 3200 103102106Wireless M-Bus Water consumption registration. -
Kamstrup - flowIQ Gateway 103102107Gateway communication Water-meter gateway registration. -
Kamstrup - flowIQ 2101 103102108Wireless M-Bus Water consumption registration. -
Kamstrup - MULTICAL 603 as water meter 103102109Wireless or wired M-Bus Water consumption registration. -
Sensus - HRI-B4 103103101Pulse or wired M-Bus Water-meter pulse/interface registration. -
Sensus - HRI-Mei B4 103103102Pulse or wired M-Bus Water-meter pulse/interface registration. -
Sensus - iPERL 103103103Wireless M-Bus Water consumption registration. -
Comac Cal - Flow 38 103113101RS485 Modbus RTU Water flow registration. -
Weather and level sensors
Device
DEVMODEL#
Connection path
Purpose
Notes
Thies Clima - Auto 107109100RS485 / serial driver Auto-detects supported Thies Hygro-Thermo-Baro variants before using the detected model path. Use for normal Thies Hygro-Thermo-Baro setup when the exact supported variant should be detected.
Thies Clima - Hydro Termo Baro 107109101RS485 / serial driver Air temperature, relative humidity, and barometric pressure. -
Thies Clima - WSC10 107109102RS485 / serial driver Compact weather station values. -
Thies Clima - WSC11 107109103RS485 / serial driver Weather values such as wind, precipitation/status options, brightness/radiation, temperature, humidity, pressure, and GPS/time data. -
GILL - MaxiMet GMX600 107110101RS485 / serial driver Compact weather station values including wind, temperature, humidity, pressure, precipitation, and compass/GPS options. -
OTT CBS - Bubble Sensor 107111101RS485 / serial driver Water level by bubble sensor principle. -
Siemens - SITRANS LR110 107116101RS485 / serial driver 80 GHz radar level measurement up to 15 m. -
Siemens - SITRANS LR120 107116102RS485 / serial driver 80 GHz radar level measurement up to 30 m. -
Thies Clima Auto uses 107109100 to identify supported Hydro Termo Baro variants. Only 1.1006.54.081 has the specific setup row 107109101.
Thies variant
Use
Notes
1.1006.54.080 107109100 AutoAuto-detected Hydro Termo Baro variant.
1.1006.54.081 107109100 Auto or 107109101Specific setup row is available when this exact variant must be documented.
1.1006.54.087 107109100 AutoAuto-detected Hydro Termo Baro variant.
1.1006.54.141 107109100 AutoAuto-detected Hydro Termo Baro variant.
1.1006.54.160 107109100 AutoAuto-detected Hydro Termo Baro variant.
1.1006.54.161 107109100 AutoAuto-detected Hydro Termo Baro variant.
1.1006.54.741 107109100 AutoAuto-detected Hydro Termo Baro variant.
1.1006.54.749 107109100 AutoAuto-detected Hydro Termo Baro variant.
1.1006.54.760 107109100 AutoAuto-detected Hydro Termo Baro variant.
1.1006.54.761 107109100 AutoAuto-detected Hydro Termo Baro variant.
1.1006.54.762 107109100 AutoAuto-detected Hydro Termo Baro variant.
1.1006.54.780 107109100 AutoAuto-detected Hydro Termo Baro variant.
1.1006.54.781 107109100 AutoAuto-detected Hydro Termo Baro variant.
Analog instruments use controller analog inputs. They do not use DEVMODEL# unless a separate driver profile is specified.
Instrument
Connection path
Purpose
Where to continue
Thermo/Hygro transmitter
2 x AI
Temperature and humidity measurement through analog transmitter signals.
Analog Transmitter Wiring
Generic 4-20 mA or 0-10 V transmitter
AI
Project-specific temperature, pressure, level, humidity, or other analog measurement.
Analog Transmitter Wiring
Digital input / counter instruments
Digital input and counter instruments expose pulses or contact changes. Detailed DI/counter setup pages will be expanded as the setup path is released.
Instrument
Connection path
Purpose
Setup status
Rain Gauge Professional
DI/counter pulse input
Precipitation measurement by pulse counting, for example tipping-bucket style rain registration.
Setup page pending.
Rain Gauge and Snow sensor Meteorological
DI/counter pulse input and related field-instrument setup
Precipitation and snow-related meteorological registration.
Setup page pending.
Generic pulse instrument
DI/counter pulse input
Meter pulses, pulse flow, or other count-based field values.
Setup page pending.
1-Wire instruments
1-Wire is used for simple temperature measurement where supported by the product IO list.
Instrument
Connection path
Purpose
Where to continue
1-Wire temperature sensor
1-Wire
Simple temperature values, for example soil temperature in agriculture installations.
1-Wire Temperature
Cookies on Vika Help
Vika Help uses necessary browser storage and, if you allow it, statistics cookies for Google Analytics. You can accept all, reject all, or open settings.
Accept all
Reject all
Settings
Cookie settings
Choose which categories may be used on Vika Help.
Necessary
Always on. Required to remember your consent choice and keep the documentation shell working as intended.
Statistics
Allows Google Analytics to measure aggregate use of the documentation site.
Save settings
Reject all
Close